Development of Dual PZT Based Impedance Measurement Techniques for Large-Scale Structures
Development of Dual PZT Based Impedance Measurement Techniques for Large-Scale Structures [1364]
Автор(ы): H.J. Lim, H.M. Song, H. Sohn
Количество страниц: 8
Год: 2012
Аннотация[305 КБ] 
Код: 10850
Описание
6th European Workshop on Structural Health Monitoring. Dresden. Germany. 2012. Report. In this study, new impedance measurement techniques are developed specially for structural health monitoring of large-scale structures. Electromechanical (EM) impedance based damage detection techniques, which utilize the electromechanical coupling effect between a piezoelectric transducer such as lead zirconate titanate (PZT) and a host structure, have been shown to be very sensitive to local damage near the PZT. However, when the impedance of the host structure becomes excessively large compared to that of the PZT, the impedance measurement becomes difficult. This impedance mismatch has been hampering the application of the impedance based damage detection techniques to large-scale structures. In this study, new impedance measurement techniques are developed for impedance measurement of large-scale structures using a dual PZT transducer, which is composed of two separate but concentric PZT segments. Impedance signals obtained by the proposed techniques are compared to those measured by conventional self-sensing circuit and commercial impedance analyzer. It is demonstrated that the proposed techniques can successfully measure the EM impedance of areal-scale bridge structure even then the conventional techniques fail to do so.